RKI Instruments, M-Series, Low Cost
![]() Click to enlarge |
|
From RKI Instruments,
The "M Series" low cost CO/H2S transmitter, a highly reliable and cost effective basic 4-20 mA transmitter for the detection of carbon monoxide, or hydrogen sulfide. The electronics are protected inside a plastic enclosure to avoid damage from mechanical abuse, water, dust or corrosion. Sensors for H2S and CO are long life and typically last 2 - 3 years.
Operating from 24 VDC (11VDC to 30 VDC), the M Series provides a 4-20 mA signal which can be connected to a wide variety of controllers. The low cost CO/H2S can be used either indoors or in semi-enclosed areas.
The only tools required to calibrate the low cost CO/H2S transmitter are a voltmeter, screwdriver, and calibration gas. Zero and calibration functions are performed by adjusting potentiometers on the amplifier board. The amplifier board has test jacks for the connection of a voltmeter for calibration purposes. Sensor response is viewed on the voltmeter as a 100mV to 500mV signal. Field calibration can be performed easily and quickly by one person.
Features Include:
- Water/dust resistant housing
- Available for H2S and CO
- Long life sensors (2 + years typical)
- Competitively priced
- Compact design
Applications Include:
- Water & wastewater treatment plants
- Pulp & paper mills
- Gas, telephone & electric utilities
- Parking garages
- Manufacturing facilities
- Loading docks
Specifications
|
Part # |
H2S |
CO |
|
Min Operating |
11 VDC |
|
|
Max Operating |
30 VDC |
|
|
Max Current |
25 mA |
|
|
Signal Output |
4 mA at 0 ppm H2S |
4 mA at 0 ppm CO |
|
Response |
20 seconds to 90% |
45 seconds to 90% of concentration |
|
Operating Environment |
||
|
Location |
Indoors or semi-enclosed areas |
|
|
Temperature |
0 to 120° F |
|
|
Humidity |
0 - 99% RH, |
|
|
Housing |
Plastic, water / dust resistant enclosure |
|
|
Sensor |
||
|
Type |
Electrochemical |
|
|
Life Expectancy |
2 years normal service when intermittently exposed to H2S |
2 to 3 years normal service |
|
Controls |
||
|
Zero |
Sets transmitter output to 4 mA with zero output from H2S sensor |
Sets transmitter output to 4 mA with zero output from CO sensor |
|
Span |
Sets transmitter output to 20 mA with 100 ppm output from H2S sensor |
Sets transmitter output to 20 mA with 300 ppm output from CO |
|
Tools Needed |
Screwdriver and voltmeter used to make adjustments |
|
* Factory Specifications are subject to change without notice.